Question: In what format are the single images stored?
Answer: The LuxWare configuration tool offers four standard formats for storing single camera
frames:
*.TIFF format: the lowermost eight bits (MSB) per pixel are stored.
*.PNG format: In 8-bit images, the lowermost eight bits (MSB) of each pixel are stored;
in 10/12/14/16-bit images, 16 bits (MSB) are stored.
*.PGM format: In 8-bit images, the lowermost eight bits (MSB) of each pixel are stored;
in 10/12/14/16-bit images, 16 bits (MSB) are stored. In addition, the PGM file contains a
file header in which, among others, the pixel format and the image geometry are stored.
*.PPM format: the RGB values are stored as ASCII data.
Question: How does the LuxWare software communicate with the camera?
Answer:The software uses a scriptable ASCII log; for the description see chapter 'Description of the
LOGLUX
i5 CL communication log'.
Question:What does the error message Invalid value read, maybe camera not initialised“
mean?
Answer:A register read by the LuxWare configuration software contains an invalid value. In this
case, you should initialize the active profile using the values of one of the pre-defined
profiles, or copy the values of another profile to the active profile.
Question:Is framegrabber 'xyz' supported?
Answer: CameraLink
framegrabbers are supported in two ways. KAMERA WERK DRESDEN
GmbH offer several CameraLink
framegrabbers which are supported by the LuxWare
configuration tool. Other CameraLink
framegrabbers may be used to configure the
LOGLUX
i5 CL camera by means of the INI file of the LuxWare configuration tool (see
Adding a non-supported CameraLink
framegrabber').
Question:Why does my supported framegrabber communicate so slowly or faultily?
Answer: Depending on the framegrabber used, more or less faults occur as regards the
framegrabber's support of the serial API. This may result in a slow-down of the
communication or in a faulty communication with the camera. The remedy is to use the
serial COM port of the LOGLUX
i5 CL camera (see 'Using software-supported
framegrabbers on the serial COM port of the LOGLUX
i5 CL camera ').
Question:My LOGLUX
i5 CL camera is connected but not detected. Why?
Answer: First check if the host system (PC/IPC) and camera as well as camera and power supply
unit are properly connected. Moreover, make sure the system load on the hardware of the
host system is as low as possible during the LOGLUX
i5 CL search process since too
heavy a load might result in an exceeding of the communication time.
Adding a non-supported CameraLink
framegrabber
If your CameraLink
framegrabber is not supported by the LuxWare configuration tool, the INI file of
the software may be used for configuring the LOGLUX
i5 CL camera.
To this end, modify the INI file 'LuxConfig.ini' - it is found in the same directory as the configuration tool
- as follows, and add the following lines, using a simple text editor:
[GenericCameraLinkDevice]
InterfaceLibrary=clser<xxx>.dll
MinPortId=<MinPort>
MaxPortId=<MaxPort>
Description=<My own powerful framegabber>
Explanation of the individual lines: